Notes
After installation and initial startup, the batteries of the Th24-DoormAster should be
charged continuously for the first 12 hours. This takes place automatically via the PoE-
powered T24 door station using the MxBus two-wire cable.
During this time, the electrical door opening function should
not be used (except for functional testing). This will maximize
and extend the battery life of the high-quality NiMH batteries
(industry standard) to several years at normal use.
When a battery has been completely drained, a functional
test can only be carried out after the red LED has turned o
(after approx. 15 minutes).
When replacing the batteries, always be sure to use original batteries. You can purchase
these directly from MOBOTIX or your MOBOTIX partner.
5.2.3 Exchanging T24-Info Info Module
The door station remains operational despite the info module
malfunctioning or being exchanged. Because of this, you do
not need to run a system restore after exchanging it.
Proceed As Follows:
1. Disconnect the door station from the power supply (for example, remove the
network plug).
2. Remove the defective info module from the module frame as described in the
T24 System Manual Part 1/Section 2.4.6 (Removing And Exchanging Modules).
3. Exchange the info modules. Take care not to damage the cabling or mix up the
connections. The connection diagrams are provided in the T24 System Manual Part 1.
4. Power up the system again. After an automatic reboot, the door station is ready
for operation again.