Mobotix MX-KEYPAD1-EXT-SV Technical Information Seite 107

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 150
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 106
107/148
Installing The Indoor Unit T24-Info2wire+
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • [email protected]
2. Power supply from an external 48 V DC power supply unit
Connection: via two contact terminals either on the T24-Info2wire+ info module or on the
indoor unit.
Advantage: flexible voltage connection option and direct connection of a router/switch
for connecting remote stations (for example, Fritz!Box WLAN).
Extending The Range
A further advantage of Mx2wire+ is that it allows the range of a connection to be extended
considerably using a two-wire cable up to 500 m long (a T24 connection using a network
cable is limited to 100 m). For detailed technical information on the T24 version with
Mx2wire+ technology, see Section 1.1.5.
Two-wire cable
Data and power
T24-Info2wire+
indoor unit
Switch, e.g.,
Fritz!Box
With T24-Info2wire+
info module
48-57 V DC
Power supply
Seitenansicht 106