108/148
T24 System Manual Part 1: Installation
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
2.6.2 Mounting Instructions
Mounting Options
In addition to an on-wall installation using the supplied surface-mounted socket, you
can also choose to install the T24-Info2wire+ indoor unit using a standard in-wall socket
or a cavity socket (for wood or plasterboard, for example). Included in the delivery is a
cavity socket of very high quality with soft rubber gaskets on the rear that need to be
punctured by the two wires that feed in. The tight seal provided here is far superior to that
oered by standard cavity sockets without this feature.
Please follow the installation instructions in Section 2.5.3. They also apply to the
T24-Info2wire+ indoor unit.
Preparing And Testing The Two-Wire Cable
In general, Mx2wire+ is used with existing cables (bell wire). When cables have more than
two wires, make sure (color coding) that the same cable pair is used for both Mx2wire+
units (see figure). Approximately 5 mm of insulation must be stripped from both ends
of the two-wire cable.
Prior to installation, test the cable connection to ensure that it is functioning properly
(if necessary, draw up a test chart).
In-wall socket Cavity socketSurface-mounted socket
T24-Info2wire+
info module
T24-Info2wire+
indoor unit
\*/<$ -&+5
-&#$?$'; 2<$$7$2
P("# W$0&/<$ 1"#$2Q